| Model: 936004 |
 |
|
Output Wiring Diagram

Power
Relay
AC Adapter
Optional
panel-mount antenna
|
|
Features
Up to 1500 Feet
( 450 m ) of
Line-of-Sight Range
Compatible with 6011 6014 6018 Transmitters
Measured Line-of-Sight Range of 1,500 Feet
Quick-Learn Programming, Selectable Supervision
Individual Outputs Per RF Channel and for Alarm, Low
Battery, and Status Trouble Reports (Connects to Base Panel)
7-Segment Channel Display (Decimal Point Indicates RF
Activity);
LED Indication for Alarm, Low Battery, and Status
Over one million factory
pre-set codes are available and all receivers
"learn" the
transmitter ID
OUTPUT OPTIONS
Type: Open collector
Mode: Factory set to normally open; can be globally selected as
normally closed by internal jumper
Current Rating: 100 mA maximum per output point
Optional Power
Relay
Momentary: 4-second momentary closure on alarm
Toggle: Alternate alarm action (toggle on, toggle off)
Latch: Requires manual reset at receiver, or operates as a follower
with transmitters
DISPLAY OUTPUT
Channel Display: One 7-segment LED indicator; displays flashing
center dash in power on an standby; displays channel ID during alarm
condition along with alarm condition LED; automatically clears when alarm
output restores; displays "P" and channel ID during programming
mode
RF Activity: Indicated by decimal point on 7-segment display;
indicates radio receiver activity; flashes with received data
Alarm Condition: Three LED indicators - alarm, low battery, and
status; displays conditions with corresponding channel ID
|
Specifications
Number of Channels: 4-Channels, supervised
Receiver Carrier Frequency: 315 MHz Bandwidth: 400 KHz typical
Receiver Sensitivity: -102 dBm typical at each antenna
Modulation: Type A1D, PPM (pulse position modulation)
Measured Range: 1,500 feet typical, with most standard stationary transmitters
Transmitter Capacity: 32 total with any distribution between
channels
(Note: learning multiple transmitters into any channel will
defeat device supervision)
Operating Voltage: 10.2 to 14.4 VDC or 12 to 16 VAC
Operating Current: Standby: 30 Ma; Alarm: Up to 120 mA
Operating Temperature: 32° to 140° F (0° to 60° C)
Dimensions: 7.25 in L x 1 in W x 5 in H (185 x 25.4 x 127 mm)
Space Required for Installation: 7.5 in L x 14.0 in H
Antennae: Two, 9-1/2 in wire whip antennae (supplied)
Mounting Hardware: Four #6 x 1 1/4 in wood screws (supplied)
|
 |
Receiver Operating Parameters:
Status Supervision: Monitored on each channel for hourly status
transmissions, reports status exception if no transmissions received
within last 8-hour time period; one common status output provided for all
channels; 7-segment display indicates channel where violation occurred;
exception set and cleared by channel
Enable Options: Status supervision enabled per channel; status
enabled by cutting proper jumper per channel; factory default disabled;
Note: with status supervision monitoring, it is not recommended to have
more than one transmitter learned per channel
Low Battery Supervision: Monitors each transmitter for low battery
alarm; reports if any learned transmitter low battery signal received; one
common low battery output for all transmitters; 7-segment display
indicates channel where low battery occurred; low battery set and cleared
by individual transmitters; transmitter that sends low battery report must
send a good battery signal to clear low battery condition
Program Mode: Enabled by program jumper; remove to enter program
mode
Transmitter Learn: Momentary press and release desired channel learn
button; activate transmitter with five seconds to learn it into desired
channel
Memory Erase: Hold appropriate channel learn button for more than 10
seconds and release; transmitters learned into that channel will be erased
from receiver memory
Memory Interrogation:
Hold appropriate channel learn button for more than five and less
than 10 seconds; alarm LED will flash the number of transmitters learned
into selected channels
| |
|